TELEMECANIQUE XCSE7513 SAFETY LIMIT SWITCH XCS-E7513 W/ KEY-TONGUE XCS-Z03
Main | |
---|---|
range of product | Preventa Safety detection |
product or component type | Safety switch |
component name | XCSE |
design | Rectangular |
material | Metal |
head type | Key operated turret head |
contacts type and composition | 2 NC + 1 NO |
contacts operation | Slow-break, break before make |
solenoid contacts type and composition | 1 NC + 1 NO (slow-break, simultaneous) |
cable entry | 2 entries tapped 1/2" NPT |
electromagnet interlocking | Locking on energisation and unlocking on de-energisation of solenoid |
[Us] rated supply voltage | 24 V (- 20...10 %) |
electrical connection | Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end |
number of poles | 3 |
locking options description | With interlocking, locking by solenoid |
local signalling | 2 LEDs green or orange (guard open/guard closed and locked) |
signalling circuit voltage | 24/48 V (voltage limits: 20...52 V) |
Complementary | |
positive opening | With NC contact |
supply voltage type | AC/DC |
supply frequency | 50/60 Hz |
load factor | 1 |
power consumption in VA | 10 VA (inrush) 10 VA (sealed) |
signalling circuit type | AC/DC |
signalling circuit consumption | 7 mA |
mechanical durability | >= 1000000 cycles |
minimum actuation speed | 0.01 m/s |
maximum actuation speed | 0.5 m/s |
[Ie] rated operational current | 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 |
[Ithe] conventional enclosed thermal current | 6 A |
[Ui] rated insulation voltage | 50 V for signalling circuit conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-5-1 |
protection type | Overvoltage protection for signalling circuit |
short circuit protection | 10 A cartridge fuse type gG (gl) |
actutr forcible withdrawal rtc | 2000 N |
actuator force for extraction | >= 20 N |
operating rate | 10 cyc/mn for maximum durability |
safety level | Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
safety reliability data | B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) |
body material | Zamak |
head material | Zamak |
depth | 44 mm |
height | 146 mm |
width | 98 mm |
product weight | 1.14 kg |
Environment | |
standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14 |
product certifications | CSA UL |
protective treatment | TC |
ambient air temperature for operation | -25...40 °C |
ambient air temperature for storage | -40...70 °C |
vibration resistance | 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
shock resistance | 10 gn for 11 ms conforming to IEC 60068-2-27 |
class of protection against electric shock | Class I conforming to EN/IEC 60536 |
IP degree of protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Offer Sustainability | |
Sustainable offer status | Green Premium product |
RoHS (date code: YYWW) | Compliant - since 1150 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity |
REACh | Reference not containing SVHC above the threshold |
_________________________________________________________________